1 2 / 4 / 8 port VoIP Gateway SIP and H.323 User’s Manual Version 1.0
10 Microsoft Windows to ping the router. Click Start -> Programs -> MS-DOS Prompt. A command mode window will open. Type “ping 10.10.10.1” (de
11 Setup Wizard: 1. WAN Type Setup: Sets/changes the WAN port Type like “Fixed IP”, “DHCP Client” or ”PPPoE”.Usually the router functions as a bo
12 Advanced Configuration: Advanced Setting Label Network Setup Label WAN Setting Sets/changes the WAN port Type like “Fixed IP”, “DHCP Client
13 VoIP Basic The S Series Gateway support 2 / 4 / 8 phone/line for SIP and H.323 VoIP call applications. You can configure these ports from this m
14 Management Label Save Configuration You can save configuration and restart the gateway with the default configuration or with the current runnin
15 n more details of WAN Port Internet access and broadband access setup. When you click “WAN Port Type Setup” from within the Wizard Setup, the fo
16 User Name: Enter User Name provided by your ISP Password: Enter Password provided by your ISP. Retype Password: Enter Password to confirm agai
17 Bridge Mode: Select S series Gateway as bridge. NAT mode: LAN IP Network Configuration IP Address: Private IP address for connecting to a loca
18 this Gateway is not registered to any H.323 Gatekeeper or any SIP Proxy Server. This setting can also assign some dialing plan to local ports (in
19 4.1 Network Configuration: 4.1.1 WAN Port Type Setup For most users, Internet access is the primary application. The S400/S200 Series Gateway
2 Table of Contents TABLE OF CONTENTS 2 0 PREFACES 4 0.1 ABOUT THIS MANUAL 4 0.2 COPYRIGHT DECLARATIONS 4 0.3 TRADEMARKS 4 0.4 SAFETY INSTRUCTIONS 4
20 PPPoE for ADSL Some ISPs provide DSL-based service and use PPPoE to establish communication link with end-users. If you are connected to the In
21 4.1.2 Configuring LAN IP Address and DHCP Server There are two kinds of network feature to configure: Bridge Mode and NAT Mode Bridge Mode: S
22 external broadband device. The LAN IP address/netmask is for private users or NAT users, and the WAN IP address/netmask is for public users. LAN
23 Private IP: Specifies the private IP address of the internal host offering the service. Private Port: Specifies the private port number of the
24 Configure the numbering with FXS / FXO ports. (Depending on model) FXS Number: The representation number is the phone number of the telephone t
25 H.323 Parameters Label H.323 ID Sets the unique name of this Gateway, that is communicated as part of H.323 messaging.. Primary Gatekeeper IP A
26 H.323 Gatekeeper ID The Gatekeeper ID; usually do not need to set this field unless the gatekeeper must need this value. Voice Cap Prefix Let us
27 In the “Outgoing Dial Plan Configurations” settings: Maximum Entries : 50 “Outbound number” is the leading digits of the call out dialing nu
28 In the “Incoming Dial Plan Configurations” settings: Maximum Entries : 50 “Inbound number” is the leading digits of the dialing number.
29 Port 1: FXO was connected to PSTN. Port 2: FXO was connected to PSTN. Port 3: FXO was connected to PSTN. Port 4: FXO was connected to PSTN. H.323
3 4.1 NETWORK CONFIGURATION: 19 4.1.1 WAN PORT TYPE SETUP 19 4.1.2 CONFIGURING LAN IP ADDRESS AND DHCP SERVER 21 4.1.3 VIRTUAL SERVER SETUP 22 4.1.4
30 “Length of Number“ has two text fields need filled: “Min Length” and “Max Length” is the min/max allowed length you can dial. “Delete Leng
31 4.2.3 H.323 VoIP Advanced Configuration Smart-QoS: If this function is enabled, when VoIP call is occurred, the other data will be automa
32 sending the DTMF tone in the voice packet. The other is “out band”, that is, sending the DTMF tone as a signal. Sending DTMF tone as a signal cou
33 1. PSTN Call from PSTN to Office PBX and dial the extension 102 go to Gateway 2. Call to Gateway of Home by Hotline. 3. Home user needs call
34 4.2.4 Configure the VoIP protocol to SIP Protocol: (If user does not need register SIP Proxy Server, Please go to 4.2.5: SIP Dialing Plan Policy)
35 SIP Proxy Server Setting: SIP Proxy Server Label SIP Proxy Server Setting 1. Enter the SIP service IP address or domain name in this field (
36 In the “Outgoing Dial Plan Configurations” settings: Maximum Entries : 50 “Outbound number” is the leading digits of the call out dialing num
37 In the “Incoming Dial Plan Configurations” settings: Maximum Entries : 50 “Inbound number” is the leading digits of the dialing number.
38 Example2: Hunting for FXO Port Port 1: FXO was connected to PSTN. Port 2: FXO was connected to PSTN. Port 3: FXO was connected to PSTN. Port 4
39 4.2.6 SIP VoIP Advanced Configuration Smart-QoS: If this function is enabled, when VoIP call is occurred, the other data will be automatic
4 0 Prefaces 0.1 About This Manual This manual is designed to assist users in using VoIP Gateway. Information in this document has been carefully ch
40 FXS Impedance: The FXS provides 600/900 OHM impedances for selection. FXO AC Impedance: The FXO provides wild and complex ac termination imp
41 4.2.8 Traffic Monitor Traffic Monitor Display : This selection will display Network traffic of this Gateway. The status information of each voi
42 5 System Administrations 5.1 Save Configuration and Reboot Click “Save Configuration and Reboot” to save configuration and begin to restart.
43 5.3 Set To Default Configuration If you want to reboot the router using factory default configuration, click “Apply” then reset the router’ s s
44 5.5 System Information Display Function Click System Information Display to open the Online Status page. In the example,on the following page,
45 5.7 Syslog Setting Function Use Syslog server to record your Gateway log file. you can setting you syslog server IP address for this function
46 Appendix-A FAQ List 1. What is the default administrator password to login to the gateway? A: By default, your default username is “admin”, defau
47 Appendix-B Scenario Application Samples Scenario 1: H.323 VoIP Call : Peer-To-Peer Mode Gateway 1 <----------> Gateway 2
48 Scenario 2 : H.323 VoIP Call: Peer-To-Peer Mode Gateway 1 (with PBX) <----> Gateway 2 Gateway#1 Gateway#2 801 60
49 Scenario 3 : H.323 VoIP Call : Peer-To-Peer Mode Gateway 1 (with PBX/PSTN)<----> Gateway 2 Call Method : Two-Stages-Dialing
5 Note: Repair or replacement, as provided under this warranty, is the exclusive remedy of the purchaser. This warranty is in lieu of all other warr
50 Scenario 4 : H.323 VoIP Call : Peer-To-Peer Mode Gateway 1 (with PBX/PSTN) <----> Gateway 2 Call Method: One-Shot-Dialing
51 Scenario 5: H.323 VoIP Call: Peer-To-Peer Mode Gateway 2 <----> Gateway 1 (Remote Call PSTN number) Call Method: One-Shot-Dialing
52 Scenario 6 : H.323 VoIP Call : Peer-To-Peer Mode Gateway 2 <----> Gateway 1 (PSTN Call PSTN number) Call Method : One-Shot-Dialing
53 Scenario 7: H.323 VoIP Call : Register to Gatekeeper Gateway 2 <----> Gateway 1 Gateway#1 Gateway#2 801 901 Register
54 Scenario 8 : H.323 VoIP Call : Register to Gatekeeper Gateway 2 <----> Gateway 1 (Call PBX extension number) Call Method : Two-Stages-Dial
55 Scenario 9 : H.323 VoIP Call : Register to Gatekeeper Gateway 2 <----> Gateway 1 (Remote Call PSTN number with PBX) Call Method : Two-Stag
56 Scenario 10 : H.323 VoIP Call : Register to Gatekeeper Gateway 2 <----> Gateway 1 (Remote Call PSTN number with PBX) Call Method: One-Shot
57 Scenario 11 : H.323 VoIP Call : Register to Gatekeeper Gateway 2 <----> Gateway 1 (Remote Call PSTN number) Call Method : One-Shot-Dialing
58 Scenario 12 : H.323 VoIP Call : Register to Gatekeeper Gateway 2 <----> Gateway 1 (PSTN Call PSTN number) Call Method : One-Shot-Dialing
59 Scenario 13 :SIP VoIP Call : Peer-To-Peer Mode Gateway 2 <----> Gateway 1 Gateway#1 Gateway#2 801 901 Outgoing
6 1.2 Front Panel LED Indicators & Rear Panels 1.2.1 Front Panel LED Descriptions -------------------------------------------------------------
60 Scenario 14 : SIP VoIP Call : Peer-To-Peer Mode Gateway 2 <----> Gateway 1 (call PBX extension number) Call Method : Two-Stages-Dialing
61 Scenario 15 : SIP VoIP Call : Peer-To-Peer Mode Gateway 2 <----> Gateway 1 (Remote Call PSTN number with PBX) Call Method : Two-Stages-Dia
62 Scenario 16 : SIP VoIP Call : Peer-To-Peer Mode Gateway 2 <----> Gateway 1 (Remote Call PSTN number with PBX) Call Method : One-Shot-Diali
63 Scenario 17 : SIP VoIP Call : Peer-To-Peer Mode Gateway 2 <----> Gateway 1 (Remote Call PSTN number) Call Method : One-Shot-Dialing
64 Scenario 18 : SIP VoIP Call : Peer-To-Peer Mode Gateway 2 <----> Gateway 1 (PSTN Call PSTN number) Call Method : One-Shot-Dialing
65 Scenario 19 : SIP VoIP Call : Register to SIP Proxy Server Gateway 2 <----> Gateway 1 Gateway#1 Gateway#2 801 901 Re
66 Scenario 20 : SIP VoIP Call : Register to SIP Proxy Server Gateway 2 <----> Gateway 1 (Call PBX Extension number) Call Method : Two-Stages
67 Scenario 21 : SIP VoIP Call : Register to SIP Proxy Server Gateway 2 <----> Gateway 1 (Remote Call PSTN number with PBX) Call Method : Two
68 Scenario 22 : SIP VoIP Call : Register to SIP Proxy Server Gateway 2 <----> Gateway 1 (Remote Call PSTN number) Call Method : Two-Stages-D
69 Scenario 23 : SIP VoIP Call : Register to SIP Proxy Server Gateway 2 <----> Gateway 1 (PSTN Call PSTN number) Call Method : Two-Stages-Dia
7 7. RS-232 Console Port (S800 Series Only) Rs-232 port is a console port, you can use it to set up Gateway. 1.3 Unpacking Your S200 / S400 / S800
8 modify any configuration of NAT device. a. Pass through method for H.323: Gateway needs register to SK Series Gatekeeper to pass through NAT ro
9 up your management PC and connecting to the Web Configurator. Note: 1.The Web Configurator is a management utility that handles all configurations